Re: AD7699, Temperature measurement

$
0
0

Yes, we're using the internal reference. On a board at room temp (cool to the touch):

And I should have said 0.1 C/V.

 

ADC says about 5000

5000*4.096 / 65536 = 312 mV

(312-283)+25 = 54, no way!

0.1*(312-283)+25 = 27.9, about right!

 

Or, referring to the first post in this thread:

0.1*(262-283)+25 = 22.9 C, more reasonable than 4.5 C at room temp.

 

But how to explain the difference between your data and 3 users?

Is it when the internal reference is used?

I'm using "11111111001101" for the config register (unipolar, scan then temp)

 

Regards,