Re: ADE7878 SPI communications

$
0
0

Hi Mani,

 

Please find below plots of MISO and SCLK while performing read operation

during SPI mode. In the plot, from the top is the SCLK signal and the one

below it is the MISO signal.  MISO line that is normally high goes low

during read operation. This means that ADE7878 is sending out something on

the MISO line. But the value I want to read from the register is not right.

I had written a value to the register and tried to read back the value from

the register. The value read from the register did not match the value

written to the register.

 

Is this error to do with the input sampling at the ADC for ADE7878?

 

Thanks!

Siva