Sigma 300 (ADAU145x) Slew Volume Rates

$
0
0

     Slew volume controls can filter noisy control inputs and minimize clicks.  Often the desired slew rate can be found by experiment.  However, in some applications it would help to know the actual slew rate a given setting yields.  For example, the ADAU1701's slew rates are described at https://ez.analog.com/message/156092#156092

 

Slew-rate-1452-block_pic.png    The -1452's slew volume controls are different (and more adjustable) than those of older SogmaDSPs,  There's separate rise and fall settings, each with several curves to choose from.  The "RC" exponential curve setting shown here provides slewing similar to that of the older slew volume blocks, thus the slew rates can be measured the same way (see the post cited above).  Testing the -1452's slewing this way results in the table below.   Slew times are given as a time constant as well as the dB/s rate often specified for SigmaDSP dynamics processors.

 

 

 

Slew-rate-1452-results_pic.png

 

    I plan to measure other slew curves as time permits.