Re: AD9364 manually initiated calibrations don't converge (quadrature, cp)

$
0
0

After some trial and error today,

the TX Quadrature calibration converges when I set the bandwidth to 10Mhz and force the

Rx NCO Frequency=Tx NCO Frequency=0.

If the bandwidth is set to 1MHz, under the same conditions, calibration fails to converge.

According to the equations in the register map manual, my clkRF=clkTF=12.288MHz, so the NCO Test Frequency = 12.288M/32=384Khz

 

Why do I need such a wide filter for the calibration? why 1Mhz or even 0.5Mhz is not enough?

once again, what do I miss?

 