Possible alternative would be the newer ADuCM320 fully specified for -40°C to 85°C!?
If you want/need to stay with the ADuC7122, the question is how long and how often you need to go to -40°C.
The silicon will not be damaged, only we cannot guarantee the full spec (specifically the analog performance) in combination of all combination of operational conditions.