I am designing an integrator to integrate output of the current sensor to obtain information on charge. I first buffered signal using an ADA4817 and use output of that amp to drive charge integrator implemented using the same op amp.
My question is can I use some of AD's analog switches to reset the integrating capacitor after the cycle is complete. Because the voltage is bidirectional I need a switch that can block both voltage polarities.
If so, is there a limitation on the maximum capacitance that the switch can safely discharge?
Regards