Hi Dominic,
Please find our answers below...
1. Has Vapour Phase Qualification been performed on this device?
>> Vapour phase qualification has not been carried out on ADV7612 but this process should not damage the part provided that the profiles specified in JEDEC standard J-STD-020 are not exceeded
2. Has the device Aqueous wash capability?
>> Washing the part should not cause a problem. In general, PCB cleaning solutions but if you should ensure that any solvents used are safe to use on semiconductor devices.
3. Could you provide details on the Waffle Tray size?
>> The parts are provided in JEDEC compliant trays of 90 pcs.
4. What is maximum number of Reflow Cycles the device can withstand?
>> Qualification against JEDEC J-STD-020 means that ADV7612 supports 3x reflows by either convection or infrared systems.
Best regards,
Joe