Re: Does the AD9361 Filter Wizard version 3.0 work correctly for receive FIRs?

$
0
0

Hi Thad,

 

Concerning the Fstop, we are comparing it with the "data rate" you specified, which is 12 MHz here. So Fstop should be less than or equal to 12/2 = 6 MHz.

 

Fstop is not compared against the rate *before* FIR decimation.

 

Thanks,

Di