Re: AD9912: Time to enter/leave Power-Down.. Full or Digital?

$
0
0

Hi,

 

I apologize for the late response on your inquiry.

For your questions:

#1 to what mode attribute the time show on page 7 at DIGITAL TIME SPECIFICATIONS section, to Full PD or to Digital PD?

-->we are still trying to verify this. We'll get back to you on this as soon as we can.

 

#2 to what mode attribute the TOTAL POWER DISSIPATION show at page 5, Full PD or Digital PD?

--> the total power dissipation at page 5 refers to Full PD bit. You may refer to the following table for the power dissipation on each bit configuration.

     

ModeVoltage (V)Current (mA)Power(mW)TOTAL POWER DISSIPATION (mW)
Full PD3.313.312.3
1.859
Digital PD3.3413.2218.4
1.8114205.2

 

We'll provide feedback on your 1st query, asap.

 