Quantcast
Channel: EngineerZone: Message List
Viewing all articles
Browse latest Browse all 36216

Re: AD9910 Phase offset validation

$
0
0

So you want to change phase offset for each chirp instead of the phase offset during a chirp?  That should be a lot easier.  I would suggest clearing the phase accumulator before each chirp that way the only difference at the start of each chirp is the programmed phase offset.  If you can then capture a chirp with a phase offset of 0, and another at a phase offset of...whatever, you should be able to compare the two captures against each other to see the difference in phase offset.