Hey,
Since there are no flags being tripped, I believe the problem is in the power train.
For a 230VAC input either your switching frequency setting of 39KHz should be changed to 70KHz for chosen L= 150uH or you should change the inductor to about 680uH to maintain the same fs of 39KHz. Can you please double check your calculations (and mine). Given the value of the inductor, it seems that you want to operate in critical conduction mode? Am I correct?